AC-160-DIN Wireless multifunctional relay for DIN-rail installation

AC-160-DIN Wireless multifunctional relay for DIN-rail installation

The wireless multifunctional relay is a component of the JABLOTRON 100 system, but it can be equally installed as a stand-alone device without a link to a control panel.

More details

Not in stock - estimated delivery is in 2 to 3 weeks

AC-160-DIN Wireless multifunctional relay for DIN-rail installation

The wireless multifunctional relay is a component of the JABLOTRON 100 system, but it can be equally installed as a stand-alone device without a link to a control panel.

It provides a switching contact relay with galvanic and safety isolation for switching 230 V/16 A power loads. The relay can respond to the status of control panel PG outputs or to the activation of devices of the JA-15x series with unidirectional communication, enrolled directly to the relay. The response can be selected from five modes – the default NATURAL function (extended copy), IMPULSE, STATUS CHANGE, SWITCH OFF and BLOCK. The relay also has a button for a direct manual status change. It allows you to update the firmware via a USB port. It is designed to be mounted on a DIN rail. It occupies one position in the system.

Specifications

Power supply

~ 230 V / 50 Hz, protective class II.

Internal power consumption

0.4 W / max. 1.5 W

Loading capacity of the power relay contacts:

(galvanically isolated from the control terminals)

protection class II:

   Max. switched voltage

250 V AC / 24 V DC

   Resistance load (cosφ=1)

max. 16 A

   Inductive, capacitive loads (cosφ=0.4)

max. 8 A

   Halogen lighting

max. 1000 W

   Minimum switched DC power

0.5 W

Wire cross section

max. 2 x 1.5 mm2; max. 1 x 2.5 mm2

Dimensions

18 x 90 x 65 mm, 1 DIN module

Environment according to

II. indoor, general, in accordance with EN 50131-1

Operating temperature range

-10 to +40 °C

Ingress protection class

IP20, IP40 for the front panel (EN 60529)

In conformity with

ETSI EN 300 220-1, EN 60950-1, EN 60947-6-1, EN 50581.